<!DOCTYPE html>
<html class="client-nojs vector-feature-language-in-header-enabled vector-feature-language-in-main-page-header-disabled vector-feature-page-tools-pinned-disabled vector-feature-toc-pinned-clientpref-0 vector-toc-not-available vector-feature-main-menu-pinned-disabled vector-feature-limited-width-clientpref-1 vector-feature-limited-width-content-enabled vector-feature-custom-font-size-clientpref-1 vector-feature-appearance-pinned-clientpref-0 skin-theme-clientpref-day vector-sticky-header-enabled" lang="de" dir="ltr"><head>
<meta charset="UTF-8">
<title>Hochdurchsatz-Screening</title>
<meta name="viewport" content="width=device-width, initial-scale=1.0">
<link rel="icon" type="image/png" href="./_res_/favicon.png">
<link rel="canonical" href="https://de.wikipedia.org/wiki/Hochdurchsatz-Screening"> <link href="./_mw_/ext.cite.styles.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.math.styles.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.wikimediamessages.styles.css" rel="stylesheet" type="text/css">
<link href="./_mw_/skins.vector.icons.css" rel="stylesheet" type="text/css">
<link href="./_mw_/skins.vector.search.codex.styles.css" rel="stylesheet" type="text/css">
<link href="./_mw_/skins.vector.styles.css" rel="stylesheet" type="text/css">
<meta name="ResourceLoaderDynamicStyles" content="">
<link href="./_mw_/ext.gadget.citeRef.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.defaultPlainlinks.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiCommonHide.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiCommonLayout.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiCommonStyle.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiDarkmode.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.dewikiResponsive.css" rel="stylesheet" type="text/css">
<link href="./_mw_/ext.gadget.specialSearch.css" rel="stylesheet" type="text/css">
<link rel="stylesheet" type="text/css" href="./_mw_/site.styles.css">
<link rel="stylesheet" type="text/css" href="./_mw_/noscript.css">
<link rel="stylesheet" type="text/css" href="./_res_/footer.css">
<link rel="stylesheet" type="text/css" href="./_res_/vector-2022.css">
</head>
<body class="skin--responsive skin-vector skin-vector-search-vue mediawiki ltr sitedir-ltr mw-hide-empty-elt ns-0 ns-subject page-Hochdurchsatz-Screening rootpage-Hochdurchsatz-Screening skin-vector-2022 action-view">
<div class="mw-page-container">
<div class="mw-page-container-inner">
<div class="mw-content-container">
<main id="content" class="mw-body">
<header class="mw-body-header vector-page-titlebar">
<h1 id="firstHeading" class="firstHeading mw-first-heading"><span class="mw-page-title-main">Hochdurchsatz-Screening</span></h1>
</header>
<a id="top"></a>
<div id="bodyContent" class="vector-body ve-init-mw-desktopArticleTarget-targetContainer" aria-labelledby="firstHeading" data-mw-ve-target-container="">
<div id="contentSub">
<div id="mw-content-subtitle"></div>
</div>
<div id="mw-content-text" class="mw-body-content mw-content-ltr" lang="de" dir="ltr"><div class="mw-content-ltr mw-parser-output" lang="de" dir="ltr">
<p><b>High-Throughput-Screening</b> (HTS), auch <b>Hochdurchsatz-Screening</b> genannt, ist eine vor allem in der <a href="Pharmaforschung" title="Pharmaforschung">Pharmaforschung</a> angewandte automatisierte Methode, bei der im Hochdurchsatz an Zehntausenden bis Millionen von Substanzen <a href="Biochemie" title="Biochemie">biochemische</a>, <a href="Genetik" title="Genetik">genetische</a> oder <a href="Pharmakologie" title="Pharmakologie">pharmakologische</a> Tests durchgeführt werden. Werden mehr als 100.000 Stoffe pro Tag untersucht, spricht man auch vom <i>Ultra</i>-High-Throughput-Screening (uHTS).<sup id="cite_ref-pmid18694386_1-0" class="reference"><a href="#cite_note-pmid18694386-1"><span class="cite-bracket">[</span>1<span class="cite-bracket">]</span></a></sup> Mittels des High-Throughput-Screening wird insbesondere nach neuen biologisch aktiven Substanzen gesucht, aus denen <a href="Leitstruktur_(Pharmakologie)" title="Leitstruktur (Pharmakologie)">Leitstrukturen</a> abgeleitet werden, um neue <a href="Arzneistoff" title="Arzneistoff">Arzneistoffe</a> zu entwickeln.
</p>
<div class="mw-heading mw-heading2"><h2 id="Durchführung"><span id="Durchf.C3.BChrung"></span>Durchführung</h2></div>
<p>Beim High-Throughput-Screening werden umfangreiche <a href="Molek%C3%BClbibliothek" title="Molekülbibliothek">Molekülbibliotheken</a> durchsucht, wobei die Suche hohe Anforderungen an die Automatisierung, die Testverfahren und die Auswertung stellt.
</p>
<div class="mw-heading mw-heading3"><h3 id="Testverfahren">Testverfahren</h3></div>
<p>Beim High-Throughput-Screening zur Entdeckung neuer <a href="Pharmakologie" title="Pharmakologie">pharmakologisch</a> aktiver Substanzen finden Target- oder Phänotyp-basierte Testverfahren (Assays) Anwendung. Entscheidend für ein korrektes Ergebnis ist, dass das Erfolgskriterium im Labor mit den Vorgängen in der Natur korreliert und das Testverfahren und die Zielvorgaben geeignet sind, das gewünschte Ergebnis zu erreichen. Eine zentrale Regel lautet: „<i>you get what you screen for</i>“.<sup id="cite_ref-2" class="reference"><a href="#cite_note-2"><span class="cite-bracket">[</span>2<span class="cite-bracket">]</span></a></sup>
</p>
<div class="mw-heading mw-heading4"><h4 id="Target-basiert">Target-basiert</h4></div>
<p>Bei Target-basierten Screenings wird die Interaktion der Testsubstanzen mit bestimmten definierten Zielstrukturen (Targets) untersucht. Targets können zum Beispiel <a href="Protein" title="Protein">Proteine</a> sein, die mit einer <a href="Krankheit" title="Krankheit">Krankheit</a> oder einem physiologischen Prozess in Verbindung stehen. Target-basierte Screenings repräsentieren in der pharmazeutischen Industrie die häufigste Form des Screenings von niedermolekularen Substanzen, um deren biologische Aktivität zu bestimmen. Sie werden in der Regel in <a href="Mikrotiterplatte" title="Mikrotiterplatte">Mikrotiterplatten</a> mit gereinigten oder ungereinigten Proteinen oder indirekt mit <a href="Zelle_(Biologie)" title="Zelle (Biologie)">Zellen</a>, die das Target-Protein bilden, durchgeführt. Die Interaktion einer Testsubstanz mit dem Target kann direkt in Bindungsassays (in der Regel über die Verdrängung eines markierten Referenzliganden vom Target) oder indirekt über die Beeinflussung der vom Targetprotein aktivierten Signalwege (z. B. Aktivierung von <a href="Second_Messenger" class="mw-redirect" title="Second Messenger">Second Messengern</a>, <a href="Protein-Protein-Interaktion" title="Protein-Protein-Interaktion">Protein-Protein-Interaktionen</a>, Protein-<a href="Phosphorylierung" title="Phosphorylierung">Phosphorylierungen</a> und Genaktivierungen) und enzymatischen Reaktionen bestimmt werden. Dazu werden insbesondere biochemische Methoden eingesetzt, bei denen ein Signal als eine Änderung der Farbintensität, der <a href="Fluoreszenz" title="Fluoreszenz">Fluoreszenz</a> oder der <a href="Lumineszenz" title="Lumineszenz">Lumineszenz</a> gemessen wird. Aus dem <a href="Signal-Rausch-Verh%C3%A4ltnis" title="Signal-Rausch-Verhältnis">Signal-Rausch-Verhältnis</a> folgt: Je stärker die Änderung der im Test ausgewerteten Signalintensität, desto besser geeignet sind die Testverfahren. Auf Lumineszenz basierende Verfahren verursachen eine vielfache Signalveränderung und sind daher oft besser geeignet als <a href="Fotometrisch" class="mw-redirect" title="Fotometrisch">fotometrischen</a> und <a href="Fluorimetrie" class="mw-redirect" title="Fluorimetrie">fluorimetrischen</a> Methoden. Eigenfarbe oder Eigenfluoreszenz von Testsubstanzen verschlechtern das Signal-Rausch-Verhältnis der fotometrischen und fluorimetrischen Messung. Auch szintimetrische Testmethoden, wie beispielsweise Radioligand-Bindungsstudien, sind hochsensitiv. Das Anfallen radioaktiver Abfälle ist jedoch ein zentrales Problem bei der Durchführung von szintimetrischen Testungen. Weitere Eigenschaften der Testsubstanzen, wie beispielsweise <a href="L%C3%B6slichkeit" title="Löslichkeit">Löslichkeit</a> und <a href="Chemische_Stabilit%C3%A4t" title="Chemische Stabilität">Stabilität</a>, spielen eine entscheidende Rolle und müssen bei der Versuchsplanung berücksichtigt werden.
</p>
<div class="mw-heading mw-heading4"><h4 id="Phänotyp-basiert"><span id="Ph.C3.A4notyp-basiert"></span>Phänotyp-basiert</h4></div>
<p>Beim Phänotyp-basierten Screening werden die Effekte von Testsubstanzen auf lebende Zellen oder Gewebe untersucht, also die Auswirkungen der Applikation der Testsubstanz auf den Phänotyp der Zelle oder des Gewebes. Der Effekt einer Testsubstanz wird anhand einer <a href="Ph%C3%A4notyp" title="Phänotyp">phänotypischen</a> Änderung, z. B. der Änderung der Zellform, des Zellwachstums oder der Zellfunktion, beurteilt. Hierbei ist es nicht erforderlich, das molekulare Target im Voraus zu kennen, oft dient das Screeningverfahren aber der Identifikation des molekularen Targets. Um das Ergebnis des Screenings nicht zu verfälschen, müssen meist eine Vielzahl an Parametern kontrolliert werden. Mit Phänotyp-basierten Screenings werden insbesondere Molekülbibliotheken durchgemustert, die höhermolekularen Verbindungen enthalten, wie beispielsweise Proteine, <a href="DNA" class="mw-redirect" title="DNA">DNA</a> und <a href="SiRNA" class="mw-redirect" title="SiRNA">siRNA</a>. Neben Zellen und <a href="Gewebe_(Biologie)" title="Gewebe (Biologie)">Gewebe</a> werden auch ganze <a href="Organismus" title="Organismus">Organismen</a>, wie beispielsweise Fischembryonen, als Modellsysteme eingesetzt. Ein Phänotyp-basiertes Screening wird oft mit Hilfe von automatisierter <a href="Mikroskopie" class="mw-redirect" title="Mikroskopie">Mikroskopie</a> (High Content Screening) durchgeführt. Oft ist ein High Content Screening gegenüber einem Target-basierten Screening durch den geringeren Durchsatz limitiert.
</p>
<div class="mw-heading mw-heading4"><h4 id="Beurteilung">Beurteilung</h4></div>
<p>Da die Durchmusterung einer kompletten Molekülbibliothek in einem High-Throughput-Screening oft mehrere Tage bis Wochen dauert, ist ein gleichbleibend zuverlässiges Arbeiten des Testverfahrens eine kritische Voraussetzung. Insbesondere bei Verwendung von Zellen muss mit einer Veränderung mit zunehmender Kultivierungszeit gerechnet werden.
</p><p>Zur Beurteilung der <a href="Robustheit" title="Robustheit">Robustheit</a> der Daten eines High-Throughput-Screenings werden Kontrollsubstanzen untersucht. Im einfachsten Fall umfassen diese einerseits Vehikel oder eine bekanntermaßen inaktive Substanz (<a href="Negativkontrolle" class="mw-redirect" title="Negativkontrolle">Negativkontrolle</a>), und andererseits eine Substanz, die zu einer maximalen Aktivierung oder Inhibition des Tests führt (<a href="Positivkontrolle" class="mw-redirect" title="Positivkontrolle">Positivkontrolle</a>). Mit Hilfe des Z'-Faktors
</p>
<dl><dd><span class="mwe-math-element mwe-math-element-inline"><span class="mwe-math-mathml-inline mwe-math-mathml-a11y" style="display: none;"><math xmlns="http://www.w3.org/1998/Math/MathML" alttext="{\displaystyle Z'=1-{\frac {3\times (\sigma _{p}+\sigma _{n})}{|\mu _{p}-\mu _{n}|}}}">
<semantics>
<mrow class="MJX-TeXAtom-ORD">
<mstyle displaystyle="true" scriptlevel="0">
<msup>
<mi>Z</mi>
<mo>′</mo>
</msup>
<mo>=</mo>
<mn>1</mn>
<mo>−<!-- − --></mo>
<mrow class="MJX-TeXAtom-ORD">
<mfrac>
<mrow>
<mn>3</mn>
<mo>×<!-- × --></mo>
<mo stretchy="false">(</mo>
<msub>
<mi>σ<!-- σ --></mi>
<mrow class="MJX-TeXAtom-ORD">
<mi>p</mi>
</mrow>
</msub>
<mo>+</mo>
<msub>
<mi>σ<!-- σ --></mi>
<mrow class="MJX-TeXAtom-ORD">
<mi>n</mi>
</mrow>
</msub>
<mo stretchy="false">)</mo>
</mrow>
<mrow>
<mrow class="MJX-TeXAtom-ORD">
<mo stretchy="false">|</mo>
</mrow>
<msub>
<mi>μ<!-- μ --></mi>
<mrow class="MJX-TeXAtom-ORD">
<mi>p</mi>
</mrow>
</msub>
<mo>−<!-- − --></mo>
<msub>
<mi>μ<!-- μ --></mi>
<mrow class="MJX-TeXAtom-ORD">
<mi>n</mi>
</mrow>
</msub>
<mrow class="MJX-TeXAtom-ORD">
<mo stretchy="false">|</mo>
</mrow>
</mrow>
</mfrac>
</mrow>
</mstyle>
</mrow>
<annotation encoding="application/x-tex">{\displaystyle Z'=1-{\frac {3\times (\sigma _{p}+\sigma _{n})}{|\mu _{p}-\mu _{n}|}}}</annotation>
</semantics>
</math></span><img src="./_assets_/eb734a37dd21ce173a46342d1cc64c92/b5647d2669158fc623592bf6c3ad124ed45a343e.svg" class="mwe-math-fallback-image-inline mw-invert skin-invert" aria-hidden="true" style="vertical-align: -2.671ex; width:23.915ex; height:6.509ex;" alt="{\displaystyle Z'=1-{\frac {3\times (\sigma _{p}+\sigma _{n})}{|\mu _{p}-\mu _{n}|}}}" loading="lazy"></span>,</dd></dl>
<p>wobei σ<sub>p</sub> und σ<sub>n</sub> die <a href="Empirische_Standardabweichung" class="mw-redirect" title="Empirische Standardabweichung">Standardabweichungen</a> der Positiv- bzw. Negativkontrolle sowie µ<sub>p</sub> und µ<sub>n</sub> die <a href="Mittelwert" title="Mittelwert">Mittelwerte</a> der Positiv- bzw. Negativkontrolle darstellen, lässt sich das Messfenster des High-Throughput-Screenings beurteilen. Assays mit Z'-Faktoren von mindestens 0,5 gelten als optimal. Auch High-Throughput-Screenings bei einem Z'-Faktor von 0 – 0,5 können noch zur Unterscheidung von aktiven und inaktiven Verbindungen geeignet sein.<sup id="cite_ref-isbn3-527-31283-8_3-0" class="reference"><a href="#cite_note-isbn3-527-31283-8-3"><span class="cite-bracket">[</span>3<span class="cite-bracket">]</span></a></sup>
</p>
<div class="mw-heading mw-heading3"><h3 id="Automatisierung">Automatisierung</h3></div>
<p>High-Throughput-Screenings sind aufwändig und werden heute nur noch mit voll- oder zumindest teilautomatisierten <a href="Laborautomatisierung" title="Laborautomatisierung">Laborautomationssystemen</a> durchgeführt. Es werden Roboter oder Automaten für das Liquid-Handling, die Datenaufnahme (Reader, Kameras) und gegebenenfalls die <a href="Zellkultur" title="Zellkultur">Zellkultur</a> eingesetzt. Das Testvolumen wird reduziert, und es werden Mikrotiterplatten mit 384, 1536 oder 3456 Näpfchen eingesetzt, um zahlreiche Proben gleichzeitig zu testen und Kosten und Zeit zu sparen.
</p>
<div class="mw-heading mw-heading3"><h3 id="Auswertung">Auswertung</h3></div>
<p>Die als Ergebnis des High-Throughput-Screening anfallenden Daten werden statistisch analysiert. Substanzen, die Messwerte jenseits eines bestimmten Schwellenwerts liefern, werden als Treffer („Hits“) eingestuft. Dennoch muss das Auftreten falsch positiver und falsch negativer Ergebnisse berücksichtigt werden. Um die Menge falsch positiver Hits zu reduzieren, wird meist ein zweites, deutlich kleineres Screening durchgeführt, das sich auf die Hits des ersten Screenings beschränkt.
</p><p>Die aus den Screenings gewonnenen Daten werden auch mit Hilfe von <a href="Chemoinformatik" title="Chemoinformatik">chemoinformatischen</a> Methoden analysiert. Dazu werden die Hits anhand ihrer molekularen Eigenschaften gefiltert. Auf diese Weise können Substanzen, die beispielsweise auf Grund reaktiver Gruppen (z. B. <a href="Aldehyd" class="mw-redirect" title="Aldehyd">Aldehyde</a>, <a href="Michael-Akzeptor" class="mw-redirect" title="Michael-Akzeptor">Michael-Akzeptoren</a> und <a href="Nitrogruppe" title="Nitrogruppe">Nitrogruppen</a>) oder einer Nichterfüllung Lipinskis <a href="Rule_of_Five" title="Rule of Five">Rule of Five</a> als ungeeignet für die weitere Entwicklung angesehen werden, von der Kandidatenliste der Leitstrukturen entfernt werden. Schließlich wählt man die vielversprechendsten Hits für die Entwicklung einer Leitstruktur aus.
</p>
<div class="mw-heading mw-heading2"><h2 id="Beschränkungen"><span id="Beschr.C3.A4nkungen"></span>Beschränkungen</h2></div>
<p>Nur wenige in einem High-Throughput-Screening identifizierte Hits haben die Qualität, als Leitstruktur klassifiziert zu werden. Ein Hit ist somit nicht automatisch eine Leitstruktur und schon gar kein <a href="Arzneistoff" title="Arzneistoff">Arzneistoff</a>. Da High-Throughput-Screenings in der Regel bei einer einzigen Testkonzentration mit Hilfe eines einzigen Assays durchgeführt werden, sind quantitative Aussagen über die Wirkstärke (Potenz) und Selektivität der Testsubstanzen nicht möglich. Viele für die Wirksamkeit und therapeutische Sicherheit einer Substanz notwendige pharmakologische Parameter wie die <a href="Zellmembran" title="Zellmembran">Zellmembran</a>- und Gewebepermeabilität sowie die Aufnahme, Verteilung, Metabolisierung, Ausscheidung (ADME) und Toxikologie werden in High-Throughput-Assays nicht oder nur unzureichend berücksichtigt. Die Weiterentwicklung von einem Hit bis hin zu einem Arzneistoff und dessen Zulassung dauert in der Regel etwa 10 bis 12 Jahre.
</p>
<div class="mw-heading mw-heading2"><h2 id="Siehe_auch">Siehe auch</h2></div>
<ul><li><a href="High_Throughput_Experimentation" title="High Throughput Experimentation">High Throughput Experimentation</a></li></ul>
<div class="mw-heading mw-heading2"><h2 id="Einzelnachweise">Einzelnachweise</h2></div>
<ol class="references">
<li id="cite_note-pmid18694386-1"><span class="mw-cite-backlink"><a href="#cite_ref-pmid18694386_1-0">↑</a></span> <span class="reference-text">Wunder F, Kalthof B, Müller T, Hüser J: <cite class="lang" lang="en" dir="auto" style="font-style:italic">Functional cell-based assays in microliter volumes for ultra-high throughput screening</cite>. In: <cite class="lang" lang="en" dir="auto" style="font-style:italic"><a href="Comb_Chem_High_Throughput_Screen" class="mw-redirect" title="Comb Chem High Throughput Screen">Comb Chem High Throughput Screen</a>.</cite> 11. Jahrgang, <span style="white-space:nowrap">Nr.<span style="display:inline-block;width:.2em"> </span>7</span>, August 2008, <span style="white-space:nowrap">S.<span style="display:inline-block;width:.2em"> </span>495–504</span>, <a class="external mw-magiclink-pmid" rel="nofollow" href="https://www.ncbi.nlm.nih.gov/pubmed/18694386?dopt=Abstract">PMID 18694386</a> (englisch).<span class="Z3988" title="ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rfr_id=info:sid/de.wikipedia.org:Hochdurchsatz-Screening&rft.atitle=Functional+cell-based+assays+in+microliter+volumes+for+ultra-high+throughput+screening&rft.au=Wunder+F%2C+Kalthof+B%2C+M%C3%BCller+T%2C+...&rft.date=2008-08&rft.genre=journal&rft.issue=7&rft.jtitle=Comb+Chem+High+Throughput+Screen.&rft.pages=495-504&rft.pmid=18694386&rft.volume=11.+Jahrgang" style="display:none"> </span></span>
</li>
<li id="cite_note-2"><span class="mw-cite-backlink"><a href="#cite_ref-2">↑</a></span> <span class="reference-text"><a href="Frances_H._Arnold" title="Frances H. Arnold">Frances H. Arnold</a>: <style data-mw-deduplicate="TemplateStyles:r261891140">
/* start https://de.wikipedia.org/ */
.mw-parser-output .webarchiv-memento a{color:inherit}
/* end https://de.wikipedia.org/ */
</style><a rel="nofollow" class="external text" href="https://web.archive.org/web/20190728055721/http://www.che.caltech.edu/groups/fha/publications/Arnold_ACR_1998.pdf"><i>Design by directed evolution.</i></a> (<span class="webarchiv-memento"><a href="Webarchivierung#Begrifflichkeiten" title="Webarchivierung">Memento</a></span> vom 28. Juli 2019 im <i><a href="Internet_Archive" title="Internet Archive">Internet Archive</a></i>) Acc. Chem. Res. (1998), Band 31, S. 125–131.</span>
</li>
<li id="cite_note-isbn3-527-31283-8-3"><span class="mw-cite-backlink"><a href="#cite_ref-isbn3-527-31283-8_3-0">↑</a></span> <span class="reference-text"><span class="book">Hanspeter Gubler: <cite class="lang" lang="en" dir="auto" style="font-style:italic">High-Throughput Screening in Drug Discovery (Methods and Principles in Medicinal Chemistry)</cite>. Hrsg.: Gerd Folkers; Jörg Hüser; Raimund Mannhold; Hugo Kubinyi. Wiley-VCH, Weinheim 2006, ISBN 3-527-31283-8, Methods for statistical analysis, quality assurance and management of primary high-throughput screening data, <span style="white-space:nowrap">S.<span style="display:inline-block;width:.2em"> </span>151–206</span> (englisch).<span class="Z3988" title="ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abookitem&rfr_id=info:sid/de.wikipedia.org:Hochdurchsatz-Screening&rft.atitle=Methods+for+statistical+analysis%2C+quality+assurance+and+management+of+primary+high-throughput+screening+data&rft.au=Hanspeter+Gubler&rft.btitle=High-Throughput+Screening+in+Drug+Discovery+%28Methods+and+Principles+in+Medicinal+Chemistry%29&rft.date=2006&rft.genre=bookitem&rft.isbn=3527312838&rft.pages=151-206&rft.place=Weinheim&rft.pub=Wiley-VCH" style="display:none"> </span></span></span>
</li>
</ol>
<div class="mw-heading mw-heading2"><h2 id="Literatur">Literatur</h2></div>
<ul><li><span class="book">Gerd Folkers; Jörg Hüser; Raimund Mannhold; Hugo Kubinyi: <cite class="lang" lang="en" dir="auto" style="font-style:italic">High-Throughput Screening in Drug Discovery (Methods and Principles in Medicinal Chemistry)</cite>. Wiley-VCH, Weinheim 2006, ISBN 3-527-31283-8 (englisch).<span class="Z3988" title="ctx_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rfr_id=info:sid/de.wikipedia.org:Hochdurchsatz-Screening&rft.au=Gerd+Folkers%3B+J%C3%B6rg+H%C3%BCser%3B+Raimund+Mannhold%3B+Hugo+Kubinyi&rft.btitle=High-Throughput+Screening+in+Drug+Discovery+%28Methods+and+Principles+in+Medicinal+Chemistry%29&rft.date=2006&rft.genre=book&rft.isbn=3527312838&rft.place=Weinheim&rft.pub=Wiley-VCH" style="display:none"> </span></span></li></ul></div><!--htdig_noindex--><div><div class="zim-footer">
Dieser Artikel wurde von <a class="external text" title="Zuletzt bearbeitet am 2025-11-28" href="https://de.wikipedia.org/wiki/?title=Hochdurchsatz-Screening&oldid=261940456">Wikipedia</a> herausgegeben. Der Text ist unter <a class="external text" href="https://creativecommons.org/licenses/by-sa/4.0/deed.de">Creative Commons Attribution-Share Alike 4.0</a> verfügbar, sofern nicht anders angegeben. Für die Mediendateien können zusätzliche Bedingungen gelten.